Select Page
Rammer_R12P

Rammer R12P

The Rammer R12P breaker is a cost-effective solution to your everyday breaking applications. The R12P’s simple impact unit design with the incorporation of a nitrogen piston accumulator and a second pressure dampening membrane type accumulator provides its users with an excellent power-to-weight ratio.

This 682kg breaker features a robust, silenced and vibration suppressed housing making it ideal for use in urban areas.

R12P is compatible with carriers ranging from 9.0 – 14.0 tonnes. The remote rockbreaker monitoring hardware RD3 is optional for Performance Line breakers.

Key Specifications

Product Weight

682 kg

Product Carrier Weight

9.0 – 14.0 t

Oil Flow Range

60 – 100 l/min

Features

  • Twin handed
  • Vibration and sound suppressed
  • Flange mounting
  • Fast-change tool system
  • RD3 (optional)
  • Original RAMMER tools
  • Piston type accumulator
  • Excellent power-to-weight ratio

Applications

  • Secondary breaking
  • Primary demolition
  • Secondary demolition
  • Recycling
  • Trenching
  • Landscaping
  • Hire Fleet

Compatible with Chisel Tool, Moil Point Tool, Performance Pyramid Tool, Standard Blunt Tool.

Specifications

Weight

682 kg

Minimum working weight, flange mounted *1

830 kg

Oil flow range

60 - 100 l/min

Impact rate (frequency)

381 - 750 bpm

Operating pressure

100 - 160 bar

Pressure relief setting *2

200 bar

Pressure relief max

220 bar

Back pressure max

15 bar

Input power
27 kW
Tool diameter
90 mm
Pressure line connection (IN)
BSPP-internal 1"
Return line connection (OUT)
BSPP-internal 1"
Pressure line size, min. inner diameter

25 mm

Return line size, min. inner diameter

25 mm

Optimum oil temperature
40 - 60°C
Allowed oil temperature range
-20 - 80°C
Optimum oil viscosity at operating temperature
30 - 60 cSt
Allowed viscosity range
20 - 1000 cSt
Carrier weight, range *3
9 - 14 t
Noise level, measured (2000/14/EC)
121 dB(A)
Noise level, guaranteed (2000/14/EC)
125 dB(A)
  • *1   Includes average mounting bracket and standard wear parts
  • *2   Minimum setting = actually measured operating pressure + 50 bar or 725 psi
  • *3   Check carrier allowed attachment weight from carrier manufacturer. Check application requirements.

Specifications are subject to change without notice.