Rammer_R07P

Rammer R07P

The Rammer R07P breaker is a cost-effective solution to your everyday breaking applications. The R07P’s simple impact unit design with the incorporation of a nitrogen piston accumulator and a second pressure dampening membrane type accumulator provides its users with an excellent power-to-weight ratio.

This 329kg breaker features a robust, silenced and vibration suppressed housing making it ideal for use in urban areas.

R07P is compatible with carriers ranging from 3.5 – 9.0 tonnes. The remote rockbreaker monitoring hardware RD3 is optional for Performance Line breakers.

Key Specifications

Product Weight

329 kg

Product Carrier Weight

3.5 – 9.0 t

Oil Flow Range

45 – 90 l/min

Features

  • Twin handed
  • Vibration and sound suppressed
  • Flange mounting
  • Fast-change tool system
  • RD3 (optional)
  • Original RAMMER tools
  • Piston type accumulator
  • Excellent power-to-weight ratio

Applications

  • Primary demolition
  • Secondary demolition
  • Recycling
  • Trenching
  • Landscaping
  • Hire Fleet

Compatible with Chisel Tool, Moil Point Tool, Performance Pyramid Tool.

Specifications

Weight

400 kg

Minimum working weight, flange mounted *1

329 kg

Oil flow range
45 - 90 l/min

Impact rate (frequency)

450 - 950 bpm

Operating pressure

80 - 140 bar

Pressure relief setting *2

200 bar

Pressure relief max

220 bar

Back pressure max

15 bar

Input power
21 kW
Tool diameter
75 mm

Pressure line connection (IN)

BSPP-internal 3/4"

Return line connection (OUT)

BSPP-internal 3/4"

Pressure line size, min. inner diameter

15 mm

Return line size, min. inner diameter

15 mm

Optimum oil temperature
40 - 60°C
Allowed oil temperature range
-20 - 80°C
Optimum oil viscosity at operating temperature
30 - 60 cSt
Allowed viscosity range
20 - 1000 cSt
Skid steer, robot weight, range *3
3.5 - 6.0 t
Carrier weight, range *3
5.0 - 9.0 t
Noise level, measured (2000/14/EC)
117 dB(A)
Noise level, guaranteed (2000/14/EC)
121 dB(A)
  • *1   Includes average mounting bracket and standard wear parts
  • *2   Minimum setting = actually measured operating pressure + 50 bar or 725 psi
  • *3   Check carrier allowed attachment weight from carrier manufacturer. Check application requirements.