Select Page
Rammer_R01P

Rammer R01P

The Rammer R01P is a cost-effective solution to your everyday breaking applications. The R01P’s simple impact unit design with the incorporation of a nitrogen piston accumulator and a second pressure dampening membrane type accumulator provides its users with an excellent power-to-weight ratio.

This 95kg rockbreaker features a robust, silenced and vibration suppressed housing making it ideal for use in urban areas.

R01P is compatible with carriers ranging from 0.7 – 2.1 tonnes. The remote rockbreaker monitoring hardware RD3 is optional for Performance Line breakers.

Key Specifications

Product Weight

75 kg

Product Carrier Weight

0.8 – 2.1 t

Oil Flow Range

15 – 25 l/min

Features

  • Twin handed
  • Vibration and sound suppressed
  • Flange mounting
  • Fast-change tool system
  • RD3 (optional)
  • Original RAMMER tools
  • Piston type accumulator
  • Excellent power-to-weight ratio

Applications

  • Primary demolition
  • Secondary demolition
  • Recycling
  • Trenching
  • Landscaping
  • Hire Fleet

Compatible with Chisel Tool, Moil Point Tool, Performance Pyramid Tool.

Specifications

Weight

75 kg

Minimum working weight, flange mounted *1

95 kg

Oil flow range

15 - 25 l/min

Impact rate (frequency)

700 - 1400 bpm

Operating pressure

80 - 120 bar

Pressure relief setting *2

150 bar

Pressure relief max

170 bar

Back pressure max

20 bar

Input power
5 kW
Tool diameter
40 mm

Pressure line connection (IN)

BSPP-internal 1/2"
Return line connection (OUT)
BSPP-internal 1/2"
Pressure line size, min. inner diameter

12 mm

Return line size, min. inner diameter

12 mm

Optimum oil temperature

40 - 60°C
Allowed oil temperature range
-20 - 80°C

Optimum oil viscosity at operating temperature

30 - 60 cSt

Allowed viscosity range

20 - 1000 cSt

Skid steer, robot weight, range *3

0.7 - 1.6 t

Carrier weight, range *3
0.8 - 2.1 t

Noise level, measured (2000/14/EC)

110 dB(A)

Noise level, guaranteed (2000/14/EC)

114 dB(A)
  • *1   Includes average mounting bracket and standard wear parts
  • *2   Minimum setting = actually measured operating pressure + 50 bar or 725 psi
  • *3   Check carrier allowed attachment weight from carrier manufacturer. Check application requirements.

Specifications are subject to change without notice.